Integrations or Automation Not Running
If an integration has stopped working — nothing is sent, nothing is received, or automatic processes no longer run — work through the checks below in order.
Each step rules out one layer, starting with the settings that disable everything at once and ending with the individual transactions. A problem at an early step makes the later ones irrelevant.
1. Is Web Connect Enabled?
Section titled “1. Is Web Connect Enabled?”Open Web Connect General Setup (Web Connect Allmänna inställningar) and verify that Web Connect is enabled.
If this is switched off, nothing runs regardless of how everything else is configured. This is the first thing to check.
2. Are the Automatic Processes Enabled?
Section titled “2. Are the Automatic Processes Enabled?”In the same view, open the Automatic Processes tab (Automatiska processer) and verify that all — or at least the relevant — processes are ticked.
Downloads and uploads are configured per integration and object, each with its own interval and enabled flag. A process that is not enabled will never run, and no error is raised — it simply does nothing.
3. Is the Integration Active?
Section titled “3. Is the Integration Active?”Open Web Connect Integrations (Web Connect Integrationer) and verify that the integration has Enabled ticked.
An integration can be disabled without any visible error. Messages simply stop being processed.
4. Is the Job Queue Running?
Section titled “4. Is the Job Queue Running?”Web Connect relies on job queue entries to move data. Verify that the relevant entries are running:
- WCM Upload — sends outgoing data
- WCM Download / Update — fetches and processes incoming data
For each entry, check that:
- Status is Ready or In Process
- Last Run has a recent timestamp
- No entry shows Error
If an entry has stopped, open it and read the error message, then choose Set Status to Ready to restart it. If it fails again immediately, the error message points to the underlying cause.
5. Are Transactions Being Created and Processed?
Section titled “5. Are Transactions Being Created and Processed?”Finally, check that transactions are actually being created and are moving.
If messages are queued but never leave, or nothing is created at all, this tells you whether the problem is upstream (nothing is being triggered) or downstream (something is being sent but failing).
The relevant views are:
| View | BC view name | Use it to |
|---|---|---|
| Outgoing Data | Web Connect Utgående data webb | See what is queued to be sent |
| Incoming Data | Web Connect Inkommande data webb | See what has been received |
| Entries | Web Connect Poster | See the full request and response for a failed call |
Still Not Working?
Section titled “Still Not Working?”If all five checks pass and the integration still does not run, the problem is more likely in the configuration of a specific object or mapping than in the automation itself. Check Web Connect Entries for the failed call and read the response from the external system.
If you are unsure, contact us before changing anything in a production environment.
